Compliance Information

This BitWise device complies with the following:

Safety Compliance


Only use the supplied desktop grounded AC-to-DC power supply with your BitWise device.


See also Safety Information


The BitWise device receives power from an external 12 Volt DC power supply.  The supplied desktop AC-to-DC power supply is required to have separate compliance certifications.  See the case of the desktop power supply for more information


EMC Compliance


Take extreme care to avoid electrical shock from being discharged into the device.  Operate in an anti-static environment


U.S. Federal Communications Commission 


Radio Frequency Interference Statement


Attention: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.


This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. However, if this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:


• Reorient or relocate the receiving antenna.

• Increase the separation between equipment and receiver.

• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/television technician for help.

• Use a shielded and properly grounded I/O cable and power cable to ensure compliance of this unit to the specified limits of the rules.


This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.



European Economic Area


This Information Technology Equipment has been tested and found to comply with EMC Directive 2014/30/EU, in accordance with:


• EN55032 (2014) Emissions:

• Class B ITE radiated and conducted emissions

• EN55024 (2010) Immunity:

• EN61000-4-2 (2009) Electrostatic discharge: ±4 kV contact, ±8 kV air

• EN61000-4-3 (2010) Radiated immunity: 3V/m

• EN61000-4-4 (2012) Electrical fast transients/burst: ±1 kV AC, ±0.5 kV I/O

• EN61000-4-5 (2014) Surges: ±1 kV differential mode, ±2 kV common mode

• EN61000-4-6 (2014) Conducted immunity: 3 V

• EN61000-4-11 (2004) Supply dips and variations: 30% and 100%

• EN50581 (2012) Technical Documentation:

• For the assessment of electrical and electronic products with respect to the restriction of hazardous substances

• EC 62368-1:2014 (EU)




Korea Communications Commission


BitWise Laboratories Inc. products are tested and certified by KCC:


Korean Compliance (KCC) Statement:

R-R-BWZ-SI-SUITE-0001


The above certification covers the following series:


BitWise PPG2CHA Pattern Generator

BitWise PELA2CHA Bit Error Location Analyzer

BitWise STEPSCOPEA Analyzer

BitWise DDR5SA Accessory

BitWise SSRPULSA Accessory



Pollution Degree Classification

A measure of the contaminants that could occur in the environment around and within a product. Typically the internal environment inside a product is considered to be the same as the external. Products should be used only in the environment for which they are rated. 


■ Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally encapsulated, hermetically sealed, or located in clean rooms. 


■ Pollution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is caused by condensation must be expected. This location is a typical office/home environment. Temporary condensation occurs only when the product is out of service.

 

■ Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation. These are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct sunshine, rain, or direct wind. 


■ Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical outdoor locations.


This product is intended for Pollution Degree 2 (as defined in IEC 61010-1).  Note: Rated for indoor, dry location use only.



Environmental Compliance

Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product’s end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately.

Complies with the applicable European Union requirements according to Directives 2012/19/EU and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, contact support@bitwiselabs.com ).


Perchlorate materials.  This product contains one CR-type lithium battery.  According to the state of California, CR lithium batteries are classified as perchlorate materials and require special handling.  See www.dtsc.ca.gov/hazardouswaste/perchlorate for additional information.



See Also

Welcome

Help Version

Service

Safety Information

Warranty